Appleby Chimney Group

Fireplace Remodel in South Pasadena Within the Unit's Clearances

Asking About Fireplace Remodel?

Scope and Parts

On a prefab unit the manual sets how close tile, stone and a mantel may sit to the opening, and what may cover the metal face. We plan the remodel around those figures, then price demolition, any panel or damper repair, the surround, the hearth and the mantel as separate lines. An older brick fireplace can be refaced too, and a gas insert can join the same project.

Manual clearances checked before any design
Noncombustible board where the listing asks
Tile, stone or plaster faces
Mantel height taken from the maker's table
Each stage on its own price line

What a Prefab Fireplace Will and Will Not Accept

Many remodel calls we get involve a metal fireplace from the 1980s or 1990s with a brass trim frame, a strip of tile and a dated mantel. All of that can change, but the unit sets the limits. The installation manual has a clearance chart showing how close combustible material can sit to the opening at each height, and a mantel that sticks out further needs to sit higher. Some units have louvers above and below the opening that move room air around the box; tile or stone cannot cover them. Some allow only noncombustible facing within a set distance of the opening, which rules out wood paneling there. And the hearth extension in front must stay at least as large as the manual asks, on a noncombustible base. We read those rules from the manual, or look up the model when the manual is lost, and the design starts from them.

Inside those limits the choices are wide. Thin stone veneer, porcelain tile, plaster, steel panels and painted brick all work on the right unit. A heavy natural stone surround needs a wall that can carry it, which on a framed chase or a standard stud wall may mean added framing, and we check that before you fall for a sample. Glass doors are a common addition, but only the doors the maker approves for that model, because an aftermarket set can trap heat the box was never tested for. A tired firebox costs least to swap while the wall is open anyway, and we price that alongside the refacing so you can weigh both. Each choice goes into a written scope with its own price line, materials named and the required clearances written beside each.

Changing the Fuel While You Remodel

A remodel is often when people decide to stop hauling wood. The options depend on the unit. A factory-built wood fireplace accepts a gas insert only when the insert maker lists that host model, and it accepts a gas log set only when the fireplace manual allows one. Where neither is allowed, the box can be replaced with a new gas unit that comes with its own vent. In homes with no fireplace at all, a sealed gas unit can go into an outside wall or a new chase, venting straight through the wall; putting one in a room that never had a fireplace costs $4,250 to $8,550 on this site, the spread set by the wall, the vent run and the gas line distance. A gas insert dropped into an existing opening that qualifies costs $2,650 to $5,350 installed.

Sequence matters. If the fuel changes, the gas line, the venting and the unit go in first, then the facing and mantel are built around the new appliance using its own clearance chart, which can differ from the old one. Doing it in the other order means tearing out new tile. We plan both on the same scope, so the trades follow the right order and nothing has to be redone. On older brick fireplaces in South Pasadena the same idea applies with different rules, since masonry has its own clearance and hearth requirements. Owners getting ready to sell sometimes do a light refacing to help photos; in that case we suggest a fireplace inspection first, so new tile does not hide a problem a buyer's inspector will still find. Cosmetic work is wasted on a box that fails.

How Appleby Handles the Paperwork

Paper First

The figure is written down before a job goes on the calendar

Listing Checked

Factory-built units are matched to the maker's label before parts are named

Part Numbers

Each line names the part and the model it fits

Your Approval

Nothing is ordered until you sign off the line

Other Appleby Services

Chimney Sweep

Soot and creosote taken off the flue walls, whether the flue is round factory pipe or square clay tile in an older brick stack.

Learn More →

Chimney Inspection

A Level 1 look at everything reachable: firebox, pipe or tile, cap, chase top or crown, and the maker's label.

Learn More →

Chimney Repair

Repairs for both kinds of chimney: listed parts on metal systems, mortar and brick on masonry, each on its own estimate line.

Learn More →

Fireplace Inspection

A check of the fireplace itself: panels, screen, doors, damper, hearth and the clearances set in the maker's manual.

Learn More →

Fireplace Repair

Cracked refractory panels, warped dampers, loose doors and torn screens on prefab units, fixed with parts listed for that model.

Learn More →

Chimney Level 2 Inspection

A deeper $375 inspection: recorded video inside the flue and a look where the pipe or brick crosses hidden framing.

Learn More →

Chimney Cap Installation

Termination caps listed for metal chimneys, screened caps for tile flues and covers spanning several flues, quoted after we measure. Size, metal and the number of flues set the price.

Learn More →

Chimney Flashing Repair

Leaks where a brick stack meets the roof, tested first, then resealed or renewed, with a cricket added where the stack is wide.

Learn More →

Chimney Masonry Repair

Brick and mortar work on older masonry stacks, priced section by section, with a mortar mixed to suit the brick.

Learn More →

Chimney Rebuilds

When brick above the roof is past repair, we rebuild it or swap it for a listed metal chimney inside a framed chase.

Learn More →

Fireplace Cleaning

Ash, soot and staining cleared from the firebox, panels, doors and hearth, with panels handled gently because they crack.

Learn More →

Gas Fireplace Cleaning

A yearly service for sealed gas units: ports and pilot cleared, glass film removed, gasket and outside termination checked, CO read.

Learn More →

Gas Fireplace Repair

Pilot outages, dead igniters, weak flames and remote faults on gas units, tested part by part before anything is ordered.

Learn More →

Fireplace Inserts

Gas inserts for masonry fireplaces, and replacement units for prefab boxes whose listing rules an insert out.

Learn More →

Pellet Stove Repair

Error codes, cold restarts and stalled feed on pellet stoves, traced with a meter at each switch, motor and board.

Learn More →

Wood Stove Repair

Door rope, glass, lining bricks, baffles and stovepipe on wood stoves, each worn part named and priced before it is fitted.

Learn More →

Gas Logs

Vented log sets for open fireplaces, with a gas line and a fixed damper stop, priced on paper first.

Learn More →

Chimney Seismic Retrofit

Bracing, strapping or a lighter upper section for brick chimneys, chosen once we see how the stack is tied into the house.

Learn More →

Chimney Crown Repair

Cracked mortar tops on brick chimneys, either coated and kept or broken off and poured again with a proper drip edge.

Learn More →

Dryer Vent Cleaning

Dryer ducts cleared from the machine to the outside hood, with crushed foil or loose joints pointed out along the way.

Learn More →

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, sized to the unit the flue will serve.

Learn More →

Chimney Leak Repair

Water showing near the fireplace traced to the chase top, cap, flashing, crown or brick, then fixed at that point.

Learn More →

Chimney Waterproofing

Repellent for porous brick stacks that soak up winter rain, put on last, once every repair above the roof is done.

Learn More →

Chimney Damper Repair

Stuck, bent or rusted dampers in brick and prefab fireplaces, fixed with the maker's parts or moved to the top of the flue.

Learn More →

Chimney Chase Cover

Rusted or sagging chase tops on framed chimneys replaced in stainless, cut to the chase with a crossbreak and skirt.

Learn More →