Appleby Chimney Group

Wood Stove Repair in South Pasadena, Read Against the Label

Asking About Wood Stove Repair?

Scope and Parts

On a wood stove we work from the door outward: rope gaskets, glass, the firebrick lining, the baffle or combustor, the body welds, then the stovepipe, its connection to the chimney and the distance to walls. Each worn item is named with its price. A cracked body or a pipe joint that has pulled apart is fixed before the next fire; a flattened door rope can usually wait a few weeks.

Door and glass rope renewed
Lining bricks swapped where cracked
Baffles and combustors ordered for the model
Pipe joints screwed and resealed
Wall and floor spacing measured

The Stove Itself

Clean burning in a stove depends on two things: seals that hold and internal parts still in one piece. When it starts to misbehave, the cause is usually one of a few things. The door gasket has gone hard and no longer seals, so the stove pulls in air past the door and the fire cannot be turned down. The glass gasket has failed the same way, or the glass itself has cracked. The baffle board or plate across the top of the box has warped, cracked or slipped out of place. Firebrick has broken and exposed the steel behind it. On newer stoves, the secondary air tubes or a catalytic combustor have burned out. We check each against the maker's parts list, test the door seal with a strip of paper around the frame, and name what has worn.

Each of those parts is model-specific. Gaskets come in set diameters and densities, baffles and tubes are cut for each firebox, and stove glass is a heat-resistant ceramic, never window glass. We order the listed part by model and serial number and fit it. When a stove has cracked castings, a warped top, or a body rusted through from years of a leaking chimney above it, the repair can cost more than a new stove, and we say so with the numbers side by side. A stove that sat cold for years may also need its connector pipe and chimney checked before the first fire, since birds and leaves often end up in the flue of an unused stove. A sweep from $400 can share that trip, priced as its own line. If the stove shows signs of a flue fire, such as blistered paint on the pipe, we look higher before relighting.

The Installation Around It

The stove's label lists the clearance to walls and furniture, what the floor pad must be made of and how far it must reach, and the pipe it needs. Installations drift from those rules over time: a bookcase moved closer, a thinner rug laid over the hearth pad, a connector pipe replaced with whatever the hardware store had. We measure and compare. The connector between the stove and the chimney should be the right gauge, with joints screwed together and the crimped ends pointing down toward the stove, and it should pass through walls or ceilings only with a listed thimble or support. A stove vented into an old masonry chimney usually needs a stainless liner to the top, sized to the stove's outlet. Where the hearth pad is too small, we price a larger noncombustible pad sized to the label.

If the stove is in a house that is about to sell, these questions come up in the buyer's inspection whether you raise them or not, so checking them first gives you time to correct them. Some buyers in South Pasadena also want to know about burn rules: the wood-burning curtailment days under the South Coast AQMD's Rule 445 cover stoves too, not just open hearths. For an owner who wants out of wood altogether, a wood stove can be replaced with a gas stove using its own listed vent, and we can price that alongside the repair. Either way, the written quote names the stove, the parts, the installation corrections and the price for each. Corrections and repairs sit on separate lines, so a buyer can see which is which. You choose which lines go ahead.

How Appleby Handles the Paperwork

Paper First

The figure is written down before a job goes on the calendar

Listing Checked

Factory-built units are matched to the maker's label before parts are named

Part Numbers

Each line names the part and the model it fits

Your Approval

Nothing is ordered until you sign off the line

Other Appleby Services

Chimney Sweep

Soot and creosote taken off the flue walls, whether the flue is round factory pipe or square clay tile in an older brick stack.

Learn More →

Chimney Inspection

A Level 1 look at everything reachable: firebox, pipe or tile, cap, chase top or crown, and the maker's label.

Learn More →

Chimney Repair

Repairs for both kinds of chimney: listed parts on metal systems, mortar and brick on masonry, each on its own estimate line.

Learn More →

Fireplace Inspection

A check of the fireplace itself: panels, screen, doors, damper, hearth and the clearances set in the maker's manual.

Learn More →

Fireplace Repair

Cracked refractory panels, warped dampers, loose doors and torn screens on prefab units, fixed with parts listed for that model.

Learn More →

Chimney Level 2 Inspection

A deeper $375 inspection: recorded video inside the flue and a look where the pipe or brick crosses hidden framing.

Learn More →

Chimney Cap Installation

Termination caps listed for metal chimneys, screened caps for tile flues and covers spanning several flues, quoted after we measure. Size, metal and the number of flues set the price.

Learn More →

Chimney Flashing Repair

Leaks where a brick stack meets the roof, tested first, then resealed or renewed, with a cricket added where the stack is wide.

Learn More →

Chimney Masonry Repair

Brick and mortar work on older masonry stacks, priced section by section, with a mortar mixed to suit the brick.

Learn More →

Chimney Rebuilds

When brick above the roof is past repair, we rebuild it or swap it for a listed metal chimney inside a framed chase.

Learn More →

Fireplace Cleaning

Ash, soot and staining cleared from the firebox, panels, doors and hearth, with panels handled gently because they crack.

Learn More →

Gas Fireplace Cleaning

A yearly service for sealed gas units: ports and pilot cleared, glass film removed, gasket and outside termination checked, CO read.

Learn More →

Gas Fireplace Repair

Pilot outages, dead igniters, weak flames and remote faults on gas units, tested part by part before anything is ordered.

Learn More →

Fireplace Remodel

New faces, mantels and hearths around a fireplace, keeping to the clearances a factory-built unit's manual sets.

Learn More →

Fireplace Inserts

Gas inserts for masonry fireplaces, and replacement units for prefab boxes whose listing rules an insert out.

Learn More →

Pellet Stove Repair

Error codes, cold restarts and stalled feed on pellet stoves, traced with a meter at each switch, motor and board.

Learn More →

Gas Logs

Vented log sets for open fireplaces, with a gas line and a fixed damper stop, priced on paper first.

Learn More →

Chimney Seismic Retrofit

Bracing, strapping or a lighter upper section for brick chimneys, chosen once we see how the stack is tied into the house.

Learn More →

Chimney Crown Repair

Cracked mortar tops on brick chimneys, either coated and kept or broken off and poured again with a proper drip edge.

Learn More →

Dryer Vent Cleaning

Dryer ducts cleared from the machine to the outside hood, with crushed foil or loose joints pointed out along the way.

Learn More →

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, sized to the unit the flue will serve.

Learn More →

Chimney Leak Repair

Water showing near the fireplace traced to the chase top, cap, flashing, crown or brick, then fixed at that point.

Learn More →

Chimney Waterproofing

Repellent for porous brick stacks that soak up winter rain, put on last, once every repair above the roof is done.

Learn More →

Chimney Damper Repair

Stuck, bent or rusted dampers in brick and prefab fireplaces, fixed with the maker's parts or moved to the top of the flue.

Learn More →

Chimney Chase Cover

Rusted or sagging chase tops on framed chimneys replaced in stainless, cut to the chase with a crossbreak and skirt.

Learn More →
Book a Visit