Factory-Built Fireplace Repair in South Pasadena

Metal Firebox or Brick?

Cracked panels, a rusted chase top, a missing cap, a pilot that quits. Fill this in and Appleby phones back to arrange a visit.

Listed partsFigures on paperBased in South Pasadena
Parts Ordered by Model Number
Written Estimate Before Work
Photos With Each Finding
Prefab and Masonry Both Covered
Based in South Pasadena
Nothing Ordered Without Your Approval
Parts Ordered by Model Number
Written Estimate Before Work
Photos With Each Finding
Prefab and Masonry Both Covered
Based in South Pasadena
Nothing Ordered Without Your Approval
Appleby Work From South Pasadena

Metal fireboxes, listed caps, chase tops and the brick stacks next door.

Each card lists the parts and checks for that job. Faults found along the way go on their own line with the part name and a figure.

01

Chimney Sweep

Soot and creosote taken off the flue walls, whether the flue is round factory pipe or square clay tile in an older brick stack.

Brush head matched to round pipe or square tile
Cap screen cleared of soot and leaves
Refractory panels vacuumed, never scraped
Room covered before any brush goes in
Read more
02

Chimney Inspection

A Level 1 look at everything reachable: firebox, pipe or tile, cap, chase top or crown, and the maker's label.

Model plate and listing label recorded
Visible pipe joints and spacers looked over
Cap and chase top seen from the roof
A photo beside every written item
Read more
03

Chimney Repair

Repairs for both kinds of chimney: listed parts on metal systems, mortar and brick on masonry, each on its own estimate line.

Chimney type settled before parts are chosen
Listed pipe sections and caps on metal systems
Open joints and loose brick on masonry
Water entry traced before a figure is given
Read more
04

Fireplace Inspection

A check of the fireplace itself: panels, screen, doors, damper, hearth and the clearances set in the maker's manual.

Rating plate photographed for your file
Panels checked against the manual's crack limits
Doors, screen and damper worked open and shut
Hearth extension and trim spacing measured
Read more
05

Fireplace Repair

Cracked refractory panels, warped dampers, loose doors and torn screens on prefab units, fixed with parts listed for that model.

Refractory panels ordered by model number
Damper blades and handles from the original maker
Door and screen kits listed for the unit
Firebrick and heat-rated mortar for brick boxes
Read more
06

Chimney Level 2 Inspection

A deeper $375 inspection: recorded video inside the flue and a look where the pipe or brick crosses hidden framing.

Recorded video from firebox to top
Firestops checked where pipe meets framing
Each still paired with a written note
Readable by buyer, seller and agent alike
Read more
07

Chimney Cap Installation

Termination caps listed for metal chimneys, screened caps for tile flues and covers spanning several flues, quoted after we measure. Size, metal and the number of flues set the price.

Termination caps matched to the pipe brand
Ember screen on every masonry cap
Multi-flue covers made to the crown
Pipe top or crown checked before fitting
Read more
08

Chimney Flashing Repair

Leaks where a brick stack meets the roof, tested first, then resealed or renewed, with a cricket added where the stack is wide.

Water test to confirm the entry point
Step and counter pieces renewed as a pair
Counter pieces set into a cut mortar line
Cricket offered when the stack is wide
Read more
09

Chimney Masonry Repair

Brick and mortar work on older masonry stacks, priced section by section, with a mortar mixed to suit the brick.

Open joints cut back and refilled
Spalled faces cut out and replaced
Mortar strength picked to suit the brick
Estimate split by section of the stack
Read more
10

Chimney Rebuilds

When brick above the roof is past repair, we rebuild it or swap it for a listed metal chimney inside a framed chase.

Brick route and metal chase route compared
Demolition and haul away on their own line
Reinforcing and roof ties on the brick route
Permit and city inspection arranged
Read more
11

Fireplace Cleaning

Ash, soot and staining cleared from the firebox, panels, doors and hearth, with panels handled gently because they crack.

Panels brushed soft, never scraped
Door glass and frames washed
Staining lifted off the face and hearth
Room covered from doorway to opening
Read more
12

Gas Fireplace Cleaning

A yearly service for sealed gas units: ports and pilot cleared, glass film removed, gasket and outside termination checked, CO read.

Glass taken off and its white film cleaned
Ports and pilot hood cleared of lint
Logs or media placed as the manual shows
Outside termination checked for blockage
Read more
13

Gas Fireplace Repair

Pilot outages, dead igniters, weak flames and remote faults on gas units, tested part by part before anything is ordered.

Millivolt test on thermopile and thermocouple
Pilot hood and orifice cleaned
Valve, module and receiver tested in turn
Parts ordered from the rating plate model
Read more
14

Fireplace Remodel

New faces, mantels and hearths around a fireplace, keeping to the clearances a factory-built unit's manual sets.

Manual clearances checked before any design
Noncombustible board where the listing asks
Tile, stone or plaster faces
Mantel height taken from the maker's table
Read more
15

Fireplace Inserts

Gas inserts for masonry fireplaces, and replacement units for prefab boxes whose listing rules an insert out.

Listing label read before an insert is offered
Liner and gas hookup inside the insert figure
Opening and depth measured for model fit
Replacement unit priced when inserts are barred
Read more
16

Pellet Stove Repair

Error codes, cold restarts and stalled feed on pellet stoves, traced with a meter at each switch, motor and board.

Code read before any panel comes off
Igniter and sensors metered
Burn pot, ash traps and exhaust path cleaned
Shipping time stated with each part price
Read more
17

Wood Stove Repair

Door rope, glass, lining bricks, baffles and stovepipe on wood stoves, each worn part named and priced before it is fitted.

Door and glass rope renewed
Lining bricks swapped where cracked
Baffles and combustors ordered for the model
Pipe joints screwed and resealed
Read more
18

Gas Logs

Vented log sets for open fireplaces, with a gas line and a fixed damper stop, priced on paper first.

Only sets listed for the firebox offered
Gas line priced from the nearest supply
Damper stop so it can never fully close
Flue looked at before the burner goes in
Read more
19

Chimney Seismic Retrofit

Bracing, strapping or a lighter upper section for brick chimneys, chosen once we see how the stack is tied into the house.

Mortar and height above the roof assessed
Bracing, strapping or a lighter top compared
Loose courses repaired before any bracing
Metal upper section in a framed chase as an option
Read more
20

Chimney Crown Repair

Cracked mortar tops on brick chimneys, either coated and kept or broken off and poured again with a proper drip edge.

Crack width measured before a choice is made
Coating kept for fine cracks only
Formed and poured again when broken through
Drip edge cast into the new overhang
Read more
21

Dryer Vent Cleaning

Dryer ducts cleared from the machine to the outside hood, with crushed foil or loose joints pointed out along the way.

Duct cleared from machine to hood
Stuck hood flaps freed
Crushed foil sections pointed out
Screws that snag lint noted
Read more
22

Chimney Liner Installation

Stainless liners for brick flues with cracked tile or a new appliance, sized to the unit the flue will serve.

Diameter set from the appliance manual
Top plate sealed and capped
Insulation wrap where framing sits close
Insert and stove connections made up
Read more
23

Chimney Leak Repair

Water showing near the fireplace traced to the chase top, cap, flashing, crown or brick, then fixed at that point.

Hose test before any figure
Chase tops checked for rust and sag
Flashing, crown and cap ruled in or out
Repair aimed at the point of entry
Read more
24

Chimney Waterproofing

Repellent for porous brick stacks that soak up winter rain, put on last, once every repair above the roof is done.

Masonry repellent that lets vapor escape
Applied after repairs, never instead of them
Brick above the roof covered face by face
Chase siding left to paint and a sound top
Read more
25

Chimney Damper Repair

Stuck, bent or rusted dampers in brick and prefab fireplaces, fixed with the maker's parts or moved to the top of the flue.

Blade, handle and spring sourced by model
Rusted masonry frames rebuilt or bypassed
Cable-worked top damper as an option
Stop fitted where gas logs need airflow
Read more
26

Chimney Chase Cover

Rusted or sagging chase tops on framed chimneys replaced in stainless, cut to the chase with a crossbreak and skirt.

Old galvanized pan removed
Stainless top made to the chase dimensions
Crossbreak pressed in to shed water
Skirt folded over the siding edge
Read more
Man lounging on a leather sofa beside a modern wood-burning fireplace

Short Version

We identify the fireplace, name its parts and write the figure down.

Appleby, South Pasadena

Metal fireboxes repaired the way their makers tested them.

Appleby Chimney Group works from South Pasadena, where older brick chimneys share streets with houses built around metal fireboxes and framed chases.

A factory-built fireplace was tested and listed as one assembly. We keep it that way: panels, dampers, doors, pipe and caps come from the maker's own list for that model.

When parts for a model are no longer made, we say so plainly and price what is left: a replacement unit, a listed insert where allowed, or a new sealed gas fireplace.

Clearance to wood framing checked on every unit

Parts ordered only after you approve the line

Maker and model recorded for your file

Masonry handled with masonry materials

Left With You

A sheet listing each part, the model it fits and its figure.

Another company could order from it line for line.

The Listing Comes First

A factory-built unit is repaired with parts its maker lists for it. If we cannot get them, we tell you so rather than improvise.

Parts Called by Name

Estimates give the part, the model and the figure, so anyone could read a line and order the same piece.

Heat and Wood Go First

Gaps between hot metal and framing, cracked panels and missing caps sit at the top of every list we write.

Houses Around South Pasadena

Craftsman brick stands next door to 1970s tract homes with metal fireboxes here, and each one is priced for what it is.

Appleby Answers

Labels, listings, caps and inspections

What owners of metal fireboxes and brick stacks ask before booking. Anything else goes through the contact form.

Check the firebox opening, or behind the grille below it, for a metal plate naming a maker and a model. A steel box lined with flat panels, a round pipe in the attic and a framed box on the roof all point to factory-built. Brick from the hearth to the top means masonry. We confirm it on the first visit and record the model.
A factory-built fireplace was tested as a system: firebox, pipe, firestops and cap together. Its listing holds only while those pieces stay as tested. A generic cap or pipe section can break that and leave hot metal too close to wood. So we order by model number, and when a maker has stopped supplying a part, we say so and price what is left.
Level 1 is $52 and covers what can be seen and reached from the room and the roof. Level 2 is $375 and adds recorded video inside the flue, plus the places where the chimney crosses hidden framing. A sale, a change of fuel, a quake or a chimney fire are the common reasons to pick the second one.
Installed caps are quoted after we measure. A single listed termination cap on a metal chimney is the simplest job. Wide covers made to fit a crown with several flues cost more. We measure before giving you the exact figure.
Only if the label or manual says that model accepts one, and many do not. Where it does, a gas insert with liner and hookup runs $2,650 to $5,350. Where it does not, the choices are a new listed unit in the same opening, or a sealed gas fireplace framed in somewhere else at $4,250 to $8,550.
Nearly always the steel pan on top of the chase. Thin galvanized pans rust, sag and hold water, and the rust washes down the siding. The same water can reach the pipe and the framing below. A stainless replacement made to the chase is the usual fix, and we price any soft wood we find under the old pan.
Yes. Under its Rule 445, the South Coast Air Quality Management District issues no-burn alerts on stagnant winter days, and they cover wood fires across this part of Los Angeles County. Gas fireplaces are not affected. Homes where wood is the only heat source have an exemption; the district publishes the details.
If your house shares a wall with its garage, has a fireplace of any type, or burns gas anywhere, California law wants carbon monoxide alarms in it. Fit one outside each sleeping area and one on every floor. We take a CO reading at every gas service, but only an alarm watches the house between our visits.
Leave lights, switches and lighters alone. Get everyone outside, then phone 911 or your gas supplier once you are well clear of the building. When the supplier has cleared the house, book us to find the fault at the valve or the fittings.
If no camera has ever been through it, yes. This corner of the county felt the 1987 Whittier Narrows and 1991 Sierra Madre shocks as well as the 1994 quake, and cracks from any of them sit inside the flue where nobody sees them from the roof. A Level 2 at $375 shows whether the tile is sound.
From South Pasadena across Los Angeles, Monterey Park, Temple City and the other cities listed on our areas page. The same rules apply everywhere we go: identify the fireplace, name the parts, put the figure on paper before work.
Five Stages

Label read, parts named, work approved

Every Appleby job follows the same order, whether the fireplace is a steel box or a brick one.

01

Read Us the Label

Send the contact form. Say whether the firebox is metal or brick, what has gone wrong, and any maker or model printed inside the opening. A rough idea of the house's age helps too.

02

Identify, Then Inspect

The first task on site is working out what the fireplace is. The label decides which parts and clearances apply, and the inspection follows from there.

03

Parts Named on Paper

Each finding is written with the part name, the model it fits and a figure, or a note that it needs measuring before it can be priced.

04

You Set the Order

Nothing is ordered or booked until you approve the line. Take the safety items now and leave the rest for later if that suits the household.

05

Fitted and Recorded

We install the parts, test the unit with you, and leave a record of the model, the parts used and anything still worth watching.

Book Through the Form

Inspections and sweeps carry set figures and are booked when we phone back.

Appleby, South Pasadena

A metal firebox, a framed chase or a brick stack: we start with the label

Fill in the form with the fault and any model you can read inside the opening. After the visit, every part goes on paper with its figure.

Services List

Inspections from $52; Level 2 with video at $375

Arrange a visit

Your name, a number and the fault you have noticed. Appleby phones back to book it.

By sending, you agree Appleby Chimney Group may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Appleby Coverage

Based in South Pasadena, reaching across the county

Los Angeles, Monterey Park and Temple City are our nearest focus cities. Search for yours to read about the houses and fireplaces we meet there.

What changes across the map

Steel fireboxes, framed chases and older brick side by side

The method stays the same everywhere: read the label, name the parts. What changes is the mix of units we find.

Tract houses

Houses from the 1970s on often carry a metal firebox, a round pipe and a framed chase with a steel top that rusts.

Condos and townhomes

Stacked units share chases and roofs, so the association and the owner often both need the same sheet.

Older brick

Craftsman and period chimneys around South Pasadena felt the 1987, 1991 and 1994 quakes; flue cracks rarely show from the roof.

Book a Visit